% RFACE.RED - Code to support execution of text from within EMODE.
%
% Author: William F. Galway
% Symbolic Computation Group
% Computer Science Dept.
% University of Utah
% Date: 8 June 1982
% Copyright (c) 1982 University of Utah
%
FirstCall := T; % Force full init when calling EMODE for first time.
DefConst(MaxChannels, 32); % Maximum number of channels supported by
% PSL.
DefConst(DISPLAYTIME, 1000); % Number of milliseconds between redisplays
% (very roughly--see code)
% Vector of "edit routines" associated with channels.
ChannelEditRoutine := MkVect(const(MaxChannels));
% Vectors of buffers associated with channel (when appropriate). Each
% entry in the vector is an expression to be evaluated (to allow extra
% indirection).
InputBufferForChannel := MkVect(const(MaxChannels));
OutputBufferForChannel := MkVect(const(MaxChannels));
% A window to "pop up" when the associated buffer is written into. This
% probably should NOT be associated with a channel?
% UNIMPLEMENTED FOR NOW. Needs MORE THOUGHT!
% OutputWindowForChannel := MkVect(const(MaxChannels));
% See below for definition of RlispDispatchList and LispDispatchList.
RlispMode := '(SetKeys RlispDispatchList) . FundamentalTextMode;
LispMode := '(SetKeys LispDispatchList) . FundamentalTextMode;
% Routines for channel I/O to & from buffers
FLUID '(
TimeSinceRedisplay % Used to decide if time to redisplay or not
% A flag for Rlisp's ON/OFF mechanism. When T, means that the "output"
% (or OUT_WINDOW) window should be "popped up" when output
% occurs.
!*outwindow
% Holds the buffername that was selected before BufferPrintChar
% switches to the output buffer.
previous_to_ouput_buffer
% Kludge flag, T when input buffer is OUT_WINDOW buffer (for M-E).
reading_from_output
EmodeBufferChannel % Channel used for EMODE I/O. Perhaps this should
% be expanded to allow different channels for
% different purposes (break loops, error messages,
% etc.) (Or, perhaps the whole model needs more
% thought! )
);
!*outwindow := T;
Symbolic Procedure OpenBufferChannel(Inbuffer, Outbuffer, Outwindow);
% Open channel for buffer I/O. Outwindow currently unused.
begin Scalar chn;
SpecialWriteFunction!* := 'BufferPrintChar;
SpecialReadFunction!* := 'BufferReadChar;
SpecialCloseFunction!* := 'CloseBufferChannel;
TimeSinceRedisplay := time(); % Get time from system
chn := Open("buffers", 'SPECIAL);
% Set up "editor" for the channel.
ChannelEditRoutine[chn] := 'EmodeChannelEdit;
InputBufferForChannel[chn] := Inbuffer;
OutputBufferForChannel[chn] := Outbuffer;
return chn
end;
Symbolic Procedure CloseBufferChannel(chn);
% Close up an EMODE buffer channel.
<<
chn := Sys2Int chn; % Sys2Int should be temporary fix?
ChannelEditRoutine[chn] := NIL;
InputBufferForChannel[chn] := NIL;
OutputBufferForChannel[chn] := NIL;
>>;
% Some history keeping stuff for debugging, we (sometimes) keep a circular
% list of characters sent to BufferPrintChar in order to hunt down obscure
% bugs.
FLUID '(BPhist BPindx);
BPhist := MkString(75, char BLANK);
BPindx := 0;
Symbolic Procedure BufferPrintChar(Chn,ch);
% "Print" a character into the buffer corresponding to channel "Chn".
% Perhaps a future version should "pop up" an associated window (or select
% a "window configuration"?), if any, (and if some flag is set?) CLEARLY,
% this needs more thought!
begin scalar tmp, outbuffername,
ErrOut!*; % ErrOut!* is a system FLUID
% Keep a history of the characters, in the circular history buffer, for
% debugging.
% (Not needed right now.)
% BPhist[BPindx] := ch;
% BPindx := if BPindx >= size(BPhist) then 0 else 1 + BPindx;
% Rebind to avoid calling self if there is an ERROR in this routine (?)
ErrOut!* := OldErrOut;
% HUM, select the appropriate buffer.
if not(CurrentBufferName
eq (outbuffername := eval OutputBufferForChannel[chn]))
then
<<
previous_to_ouput_buffer := CurrentBufferName;
SelectBuffer(outbuffername);
>>;
InsertCharacter(ch);
% Refresh after every character might be nice, but it's costly! The
% compromise is to refresh on every line--or after a time limit is
% exceeded, whichever comes first.
if ch = char EOL
then
<<
% Make sure we're in two window mode, unless also reading from
% OUT_WINDOW, so the user can see what we print into the buffer.
% Don't pop up window if !*Outwindow is NIL.
% NEEDS more thought.
if !*outwindow and not(reading_from_output) then
EnsureOutputVisible(outbuffername, previous_to_ouput_buffer);
Refresh();
>>
else if ((tmp := time()) - TimeSinceRedisplay) > const(DISPLAYTIME) then
<<
TimeSinceRedisplay := tmp;
if !*outwindow and not(reading_from_output) then
EnsureOutputVisible(outbuffername, previous_to_ouput_buffer);
Refresh();
>>;
end;
% Ensure the visibility of the outbuffername buffer, oldbuffername gives
% the "context" that the call occurs from.
Symbolic Procedure EnsureOutputVisible(outbuffername,oldbuffername);
% Don't do anything if the buffer is already visible.
% Otherwise go through a rather elaborate kludge.
if not Buffer_VisibleP(outbuffername) then
<<
SelectBuffer(oldbuffername);
% Go to "two window" mode if just one "major window" on screen, and
% it's a "text window".
if MajorWindowCount() eq 1
AND buffers_view_creator eq 'create_text_view
then
TwoRFACEWindows()
else
% Otherwise, just "create a view" into the OUT_WINDOW buffer.
select_or_create_buffer('OUT_WINDOW,NIL);
SelectBuffer(outbuffername);
>>;
Symbolic Procedure BufferReadChar(Chn);
% Read a character from at location "point" in appropriate buffer for
% channel "Chn", advance point.
begin scalar ch;
chn := Sys2Int chn; % Sys2Int should be temporary fix?
%??? if not(CurrentWindowDescriptor eq InputWindowForChannel[chn]) then
SelectBuffer(eval InputBufferForChannel[chn]);
% (End of buffer test needs to be cleaned up.)
if point = length CurrentLine
and EndOfBufferP(NextIndex CurrentLineIndex)
then
return char EOF; % "End Of File" if at end of buffer
% ****OR, should we do something like this? (Not very popular when
% tried--end of buffer was typically due to a syntax error, often very hard
% to know how to correct the problem.)
% % Prompt user for more input if at end of buffer, then continue as
% % usual.
% <<
% EmodeChannelEdit(chn, "END OF BUFFER: more input expected.");
%
% % Ultimate kludge! Get back to current buffer. (Seem to be
% % mysterious problems with "CurrentLine" inconsistencies.)
%% if not(CurrentWindowDescriptor eq InputWindowForChannel[chn]) then
%
% SelectBuffer(eval InputBufferForChannel[chn]);
% >>;
ch := CurrentCharacter(); % Get the character
if !*ECHO then % Echo to OUT_WINDOW if ECHO flag is set.
<<
BufferPrintChar(Int2Sys Chn, Int2Sys ch); % NOTE Int2Sys
% Super kludge! Get back to current window
%??? if not(CurrentWindowDescriptor eq InputWindowForChannel[chn]) then
SelectBuffer(eval InputBufferForChannel[chn]);
>>;
!$ForwardCharacter(); % Advance to next in buffer
return Int2Sys(ch); % Convert to SYSLISP integer
end;
Two_window_midpoint := NIL;
Symbolic Procedure TwoRFACEWindows();
% Enter two window mode for RLISP interface. Puts prompt information just
% below the upper window. ("Prompt" means "message window"--not EMODE's
% prompt window.)
if MajorWindowCount() neq 2 then
% Only do something if not already in "two window mode".
begin scalar old_prompt, old_msg, TopWindow;
old_prompt :=
if Prompt_Window then cdr atsoc('window_label, Prompt_Window);
old_msg :=
if Message_Window then cdr atsoc('window_label, Message_Window);
% Two_window_midpoint is location of dividing line of dashes, wrt
% ScreenBase, roughly speaking.
% (3 and 5 are rather ad-hoc guesses.)
if not numberp(two_window_midpoint) OR two_window_midpoint < 3
OR two_window_midpoint > (Row ScreenDelta) - 5
then
two_window_midpoint := Fix (0.5 * (Row ScreenDelta - 2));
Setup_Windows
list(
% Looks into current buffer
TopWindow :=
FramedWindowDescriptor(CurrentBufferName,
Coords(Column ScreenBase - 1,
Row ScreenBase - 1),
Coords(Column ScreenDelta + 2,
two_window_midpoint)),
% Looks into the "message buffer", used for error messages
% and general stuff.
Message_Window :=
UnframedWindowDescriptor('MESSAGE_BUFFER,
% Base is at two_window_midpoint
Coords(Column ScreenBase,
Row ScreenBase + two_window_midpoint),
% a single line (so delta row = 0)
Coords(Column ScreenDelta, 0)),
% Always looks into the 'OUT_WINDOW buffer,
% until we can figure out a better way to handle the
% situation??
FramedWindowDescriptor('OUT_WINDOW,
Coords(Column ScreenBase - 1,
Row ScreenBase +
two_window_midpoint + 1),
% Run down to the bottom, minus a one line
% window.
Coords(Column ScreenDelta + 2,
Row ScreenDelta
- two_window_midpoint - 2)),
% Looks into the "prompt line" buffer.
Prompt_Window :=
UnframedWindowDescriptor('PROMPT_BUFFER,
% Base is at bottom
Coords(Column ScreenBase,
Row ScreenBase + Row ScreenDelta),
% a single line (so delta row = 0)
Coords(Column ScreenDelta, 0))
);
% Restore the labels from their old values (if any).
SelectWindowContext(Prompt_Window);
window_label := old_prompt;
SelectWindowContext(Message_Window);
window_label := old_msg;
% Keep track of "minor windows".
minor_window_list := list(Prompt_Window, Message_Window);
SelectWindow TopWindow; % ??? should this be necessary?
end;
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% Set up bindings for Rlisp Mode.
RlispDispatchList :=
list(
% M-; inserts a comment--isn't nearly as nice as EMACS version yet.
cons(char meta !;, 'InsertComment),
% M-E puts us at beginning of line and then simply causes us to return
% (exit) to the caller (roughly speaking).
cons(char meta E, 'ReturnFromEmodeEdit),
% M-C-Y deletes the last "expression" printed in OUT_WINDOW.
cons(char meta cntrl Y, 'insert_last_expression)
);
% Set up bindings for Lisp Mode. (See HP-EMODEX for additions to this
% list.)
LispDispatchList :=
list(
% M-; inserts a comment--isn't nearly as nice as EMACS version yet.
cons(char meta !;, 'InsertComment),
% M-E puts us at beginning of line and then simply causes us to return
% (exit) to the caller (roughly speaking).
cons(char meta E, 'ReturnFromEmodeEdit),
% M-C-Y deletes the last "expression" printed in OUT_WINDOW.
cons(char meta cntrl Y, 'insert_last_expression)
);
Symbolic Procedure insert_last_expression();
% Insert "last expression" typed in the OUT_WINDOW buffer.
begin scalar cbuf;
cbuf := CurrentBufferName; % Remember current buffer.
SelectBuffer('OUT_WINDOW);
% "Mark" points to start of expression, "Point" gives the end.
% First, back up over any trailing blank lines.
while not BeginningOfBufferP(CurrentLineIndex) and point = 0 do
!$BackwardCharacter();
% Now, copy the text into the "kill buffer".
copy_region();
% Move back to the end of the output buffer.
!$EndOfBuffer();
% Select the original buffer.
SelectBuffer(cbuf);
insert_kill_buffer();
end;
Symbolic Procedure ReturnFromEmodeEdit();
% (Typically invoked by M-E.) Causes EMODE to return to procedure that
% called it (via "EmodeChannelEdit"). Arranges for output to go to end of
% OUT_WINDOW buffer.
begin scalar cbuf;
% Set point and mark for output buffer, unless it's also the input
% buffer.
if CurrentBufferName neq 'OUT_WINDOW then
<<
cbuf := CurrentBufferName;
SelectBuffer('OUT_WINDOW);
!$EndOfBuffer();
SetMark();
SelectBuffer(cbuf); % Switch back to original buffer.
reading_from_output := NIL;
>>
else
reading_from_output := T;
% Remember current spot, in case user wants to come back here.
SetMark();
% If we're at the end of the buffer, insert an EOL (gratis).
if Point = Length CurrentLine
and EndOfBufferP(NextIndex CurrentLineIndex)
then
<<
!$CRLF();
!$BackwardLine(); % Start out on the previous line.
>>;
% Start reading from the start of the line that M-E was typed at.
!$BeginningOfLine();
% Set things up to read from and write to EMODE buffers.
SelectEmodeChannels();
leave_dispatch_loop();
end;
% Make sure *EMODE's defined (as opposed to unbound?) at load time. Hope
% we don't load inside EMODE!
!*EMODE := NIL;
% Redefine QUIT so that it restores the terminal to echoing before exiting.
if FUnboundP('original!-quit) then
CopyD('original!-quit, 'quit);
Symbolic Procedure quit();
<<
if !*EMODE then % If invoked from "inside" EMODE.
<<
SelectOldChannels(); % Switch to original channels.
EchoOn(); % Turn echoing back on.
>>;
original!-quit();
% Fire up EMODE, if we called quit from inside it.
if !*EMODE then
EMODE(); % Select RLISP-INTERFACE mode upon restart.
>>;
Symbolic Procedure EmodeChannelEdit(chn, PromptStr);
% Invoke EMODE as the editor for a buffer channel. Display the prompt on
% "message_window".
<<
% Select "old" channels, so if an error occurs we don't get a bad
% recursive situation where printing into a buffer causes more trouble!
SelectOldChannels();
% But, keep echoing turned off, we need some other hook to restore
% echoing if an error occurs.
if null PromptStr then % Use empty string if no prompt given.
PromptStr := "";
%?? if not(CurrentWindowDescriptor eq InputWindowForChannel[chn]) then
SelectBuffer(eval InputBufferForChannel[chn]);
% Advance to end of next line, on theory that we want to move to next
% expression to evalute.
if not EndOfBufferP(NextIndex CurrentLineIndex) then
<<
!$ForwardLine();
!$EndOfLine();
>>;
ERRORSET(list('EMODE1, PromptStr),T,!*BACKTRACE);
>>;
Symbolic Procedure PromptAndEdit(PromptStr);
% Allow the user to "edit" the default input channel.
PromptAndEditOnChannel(IN!*, PromptStr);
Symbolic Procedure PromptAndEditOnChannel(chn, PromptStr);
% If there is an editor associated with the channel, call it, passing the
% channel and prompt string "PromptStr" as arguments. Always return NIL.
<<
if not null ChannelEditRoutine[chn] then
Apply(ChannelEditRoutine[chn], list(chn, PromptStr));
NIL
>>;
Symbolic Procedure MakeInputAvailable();
% THIS IS THE MAGIC FUNCTION invoked by READ, and other "reader functions".
% PROMPTSTRING!* is a global (FLUID) variable.
PromptAndEdit(PROMPTSTRING!*);
FLUID '(
OldStdIn
OldStdOut
OldErrOut
);
Symbolic Procedure SelectOldChannels();
% Select channels that were in effect when "Rlisp Interface" was started
% up. (But don't turn echoing on.) NOTE that the "old channels" are
% normally selected while EMODE is actually running (this is somewhat
% counter intuitive). This is so that any error messages created by bugs
% in EMODE will not be printed into EMODE buffers. (If they were, it might
% break things recursively! )
<<
% Postion the cursor to the bottom of the screen.
SetTerminalCursor(Column ScreenBase, Row ScreenDelta);
% Currently we avoid closing the channels. Unclear if this is right. If
% we do decide to close channels, remember not to close a channel after
% it's already closed! (In case, e.g., ErrOut!* = STDOUT!*.)
STDIN!* := OldStdIn;
STDOUT!* := OldStdOut;
ErrOut!* := OldErrOut;
RDS STDIN!*; % Select the channels.
WRS STDOUT!*;
>>;
Symbolic Procedure InsertComment();
<<
!$EndOfLine();
insert_string "% ";
>>;