%SUMMARY wPipe Isentropic pipe with work transfer. %DESCRIPTION wPipe represents an ideal (energy conserving) pipe carrying a %DESCRIPTION fluid with work transfer. To ensure energy conservation, power bonds are used and %DESCRIPTION connected by (energy conserving) TF components. %DESCRIPTION Parameter 1: c_v - specific heat of fluid %DESCRIPTION Parameter 2: Parameter passed to Density component %DESCRIPTION Ports: %DESCRIPTION [Hy_in] Pressure/volume-flow inflow %DESCRIPTION [Hy_in] Pressure/volume-flow outflow %DESCRIPTION [Th_in] Temperature/Entropy-flow in flow %DESCRIPTION [Th_out] Temperature/Entropy-flow out flow %DESCRIPTION [Shaft] Torque/angular velocity input. %ALIAS in Thermal_in,Hydraulic_in %ALIAS out Thermal_out,Hydraulic_out %ALIAS Th_in Thermal_in %ALIAS Hy_in Hydraulic_in %ALIAS Th_out Thermal_out %ALIAS Hy_out Hydraulic_out %ALIAS Work Shaft %ALIAS $1 c_v %ALIAS $2 density,ideal_gas,r %% Label file for system wPipe (wPipe_lbl.txt) % %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% % %% Version control history % %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% % %% $Id$ % %% $Log$ % %% Revision 1.1 1998/07/03 17:38:20 peterg % %% Initial revision % %% % %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% %% Each line should be of one of the following forms: % a comment (ie starting with %) % Component-name CR_name arg1,arg2,..argn % blank % Component type Density rho1 none density,ideal_gas,r rho2 none density,ideal_gas,r % Component type EMTF p2pv lin flow pv2p lin effort % Component type SS [Hydraulic_in] SS external,external [Hydraulic_out] SS external,external [Shaft] SS external,external [Thermal_in] SS external,external [Thermal_out] SS external,external % Component type TF t2u lin effort,c_v u2t lin flow,c_v