File mtt/lib/comp/compound/Control/Collocated/PIe/PIe_desc.tex artifact 1e82a62155 part of check-in a8cce33cfa


% -*-latex-*- Put EMACS into LaTeX-mode
% Verbal description for system PIe (PIe_desc.tex)
% Generated by MTT on Wed May 15 10:28:28 BST 2002.

% %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% %% Version control history
% %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% %% $Id$
% %% $Log$
% %% Revision 1.1  2000/12/28 09:13:38  peterg
% %% Initial revision
% %%
% %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%

   The acausal bond graph of system \textbf{PIe} is
   displayed in Figure \Ref{fig:PIe_abg.ps} and its label
   file is listed in Section \Ref{sec:PIe_lbl}.

\textbf{PIe} implements a collocated PI controller where:
\begin{description}
\item[w] is the (flow) setpoint at port [w]
\item[y] is the (flow) system output at port [yu]
\item[u] is the (effort) system input (control signal) at port [yu]
\end{description}

The controller transfer-function is:
\begin{equation}
  u(s) = \left [ k_p + \frac{k_i}{s} \right ] e(s) 
\end{equation}
where the \emph{error} $e(s) = w(s) - y(s)$.

MTT: Model Transformation Tools
GitHub | SourceHut | Sourceforge | Fossil RSS ]